Part Number |
Description |
Pressure Range |
Accuracy |
Process Connection |
Electrical Connection |
CAD |
---|---|---|---|---|---|---|
PT41-23000psig-1-1-6-16 PT41-23000psig-1-1-6-16/Asset/PT41-6-16-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, 1/2 NPT conduit with 3 ft cable | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A 1/2 NPT conduit with 3 ft cable | CAD N/A |
PT41-23000psig-1-1-6-8 PT41-23000psig-1-1-6-8/Asset/PT41-6-8-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A | CAD N/A |
PT41-23000psig-1-1-6-14 PT41-23000psig-1-1-6-14/Asset/PT41-6-14-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A with 1/2 NPT female conduit | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 1/2 NPT female conduit | CAD N/A |
PT41-23000psig-1-1-6-18 PT41-23000psig-1-1-6-18/Asset/PT41-6-18-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A with 3 ft cable | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 3 ft cable | CAD N/A |
PT41-23000psig-1-1-6-25 PT41-23000psig-1-1-6-25/Asset/PT41-6-25-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, M12 x 1 4 pin | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A M12 x 1 4 pin | CAD N/A |
PT41-23000psig-1-1-6-36 PT41-23000psig-1-1-6-36/Asset/PT41-6-36-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, integral cable 3 ft | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A integral cable 3 ft | CAD N/A |
PT41-23000psig-1-2-6-3 PT41-23000psig-1-2-6-3/Asset/PT41-6-3-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, bayonet 6 pin | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A bayonet 6 pin | CAD N/A |
PT41-23000psig-1-2-6-16 PT41-23000psig-1-2-6-16/Asset/PT41-6-16-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, 1/2 NPT conduit with 3 ft cable | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A 1/2 NPT conduit with 3 ft cable | CAD N/A |
PT41-23000psig-1-2-6-8 PT41-23000psig-1-2-6-8/Asset/PT41-6-8-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A | CAD N/A |
PT41-23000psig-1-2-6-14 PT41-23000psig-1-2-6-14/Asset/PT41-6-14-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A with 1/2 NPT female conduit | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 1/2 NPT female conduit | CAD N/A |
PT41-23000psig-1-2-6-18 PT41-23000psig-1-2-6-18/Asset/PT41-6-18-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A with 3 ft cable | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 3 ft cable | CAD N/A |
PT41-23000psig-1-2-6-25 PT41-23000psig-1-2-6-25/Asset/PT41-6-25-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, M12 x 1 4 pin | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A M12 x 1 4 pin | CAD N/A |
PT41-23000psig-1-2-6-36 PT41-23000psig-1-2-6-36/Asset/PT41-6-36-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 5 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, integral cable 3 ft | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A integral cable 3 ft | CAD N/A |
PT41-23000psig-1-5-6-3 PT41-23000psig-1-5-6-3/Asset/PT41-6-3-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, bayonet 6 pin | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A bayonet 6 pin | CAD N/A |
PT41-23000psig-1-5-6-16 PT41-23000psig-1-5-6-16/Asset/PT41-6-16-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, 1/2 NPT conduit with 3 ft cable | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A 1/2 NPT conduit with 3 ft cable | CAD N/A |
PT41-23000psig-1-5-6-8 PT41-23000psig-1-5-6-8/Asset/PT41-6-8-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A | CAD N/A |
PT41-23000psig-1-5-6-14 PT41-23000psig-1-5-6-14/Asset/PT41-6-14-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A with 1/2 NPT female conduit | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 1/2 NPT female conduit | CAD N/A |
PT41-23000psig-1-5-6-18 PT41-23000psig-1-5-6-18/Asset/PT41-6-18-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, DIN form A with 3 ft cable | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 3 ft cable | CAD N/A |
PT41-23000psig-1-5-6-25 PT41-23000psig-1-5-6-25/Asset/PT41-6-25-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, M12 x 1 4 pin | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A M12 x 1 4 pin | CAD N/A |
PT41-23000psig-1-5-6-36 PT41-23000psig-1-5-6-36/Asset/PT41-6-36-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 0 Vdc to 10 Vdc, 3-wire, 9/16-18 UNF 2B high pressure, integral cable 3 ft | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.5% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A integral cable 3 ft | CAD N/A |
PT41-23000psig-2-1-6-3 PT41-23000psig-2-1-6-3/Asset/PT41-6-3-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, bayonet 6 pin | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A bayonet 6 pin | CAD N/A |
PT41-23000psig-2-1-6-16 PT41-23000psig-2-1-6-16/Asset/PT41-6-16-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, 1/2 NPT conduit with 3 ft cable | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A 1/2 NPT conduit with 3 ft cable | CAD N/A |
PT41-23000psig-2-1-6-8 PT41-23000psig-2-1-6-8/Asset/PT41-6-8-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A | CAD N/A |
PT41-23000psig-2-1-6-14 PT41-23000psig-2-1-6-14/Asset/PT41-6-14-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A with 1/2 NPT female conduit | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 1/2 NPT female conduit | CAD N/A |
PT41-23000psig-2-1-6-18 PT41-23000psig-2-1-6-18/Asset/PT41-6-18-Photograph.jpg | N/A High Pressure Fixed Range Pressure Transmitter, 0 to 23000 psi gauge, ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 4 mA to 20 mA, 2-wire, 9/16-18 UNF 2B high pressure, DIN form A with 3 ft cable | Pressure Range N/A 0 to 23000 psi gauge | Accuracy N/A ±0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions | Process Connection N/A 9/16-18 UNF 2B high pressure | Electrical Connection N/A DIN form A with 3 ft cable | CAD N/A |