Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Items |
/Asset/660-Series-Pressure-Transmitter.jpg 660-3000-1-1-2-25 0 to 3,000 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output, 1/4" National Pipe Thread (NPT) Male Pressure Transducer with M12 x 1 (4 Pin) |
/Asset/660-Series-Pressure-Transmitter.jpg 660-5000-1-1-2-7 0 to 5,000 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output, 1/4" National Pipe Thread (NPT) Male Pressure Transducer with DIN EN 175301-803 Form C Electrical Connection |
/Asset/660-Series-Pressure-Transmitter.jpg 660-500-1-1-2-25 0 to 500 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output, 1/4" National Pipe Thread (NPT) Male Pressure Transducer with M12 x 1 (4 Pin) |
/Asset/660-Series-Pressure-Transmitter.jpg 660-500-1-1-2-25-ST8 0 to 500 psig, 0.25% Accuracy (Best Fit Straight Line (BFSL), 4 to 20 mA Output, 1/4" National Pipe Thread (NPT) Male Pressure Transducer with M12 x 1 (4-Pin) and 0.8 mm Threaded Orifice |
||||
Description |
N/A
|
|||||||
Type | N/A Micro-Size Transducer | |||||||
Series | N/A 660 | |||||||
Electromagnetic Rating | N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection | |||||||
Storage Temperature [Min] | N/A -40 ºC-40 ºF | |||||||
Storage Temperature [Max] | N/A 100 ºC212 ºF | |||||||
Housing Material | N/A 316 Stainless Steel | |||||||
Output Signal | N/A 4 mA to 20 mA, 2-wire | |||||||
Process Connections | N/A 1/4 in. National Pipe Thread (NPT) Male | |||||||
Electrical Connection | N/A M12 x 1 (4-pin) | N/A DIN EN 175301-803 Form C | N/A M12 x 1 (4-pin) | N/A M12 x 1 (4-pin) | ||||
Power Requirement |
N/A
10 Vdc to 36 Vdc (4 mA to 20 mA, 2-wire) 8 Vdc to 36 Vdc (1 Vdc to 5 Vdc, 3-wire) 14 Vdc to 36 Vdc (0.1 Vdc to 10 Vdc, 3-wire) |
|||||||
Pressure Range1 | N/A 0 to 3,000 psig | N/A 0 to 5,000 psig | N/A 0 to 500 psig | N/A 0 to 500 psig | ||||
Full Scale Best Fit Straight Line (BFSL) Accuracy (±)2 | N/A 0.25 % | |||||||
Stability | N/A ≤±0.2% full scale for 1 year, non-accumulating | |||||||
Service Life | N/A > 100,000,000 Load Cycles | |||||||
Compensated Temperature Range | N/A -4 to 185 ºF-20 to 185 ºC | |||||||
Note for Compensated Temperature Range |
N/A
Zero effect ± 0.01% full scale/ºF Span effect ± 0.01% full scale/ºF |
|||||||
Media Temperature Range3 | N/A -40 to 257 ºF-13 to 185 ºF-40 to 100 ºC-40 to 125 ºC | |||||||
Ambient Temperature Range | N/A -4 to 185 ºF-25 to 85 ºC | |||||||
Load Limitations |
N/A
≤(VPower-10)/0.020 Amp for 4 mA to 20 mA ≥10,000 Ω for 0 Vdc to 10 Vdc, 3-wire ≥5,000 Ω for 0 Vdc to 5 Vdc, 3-wire |
|||||||
Proof Pressure | N/A 1.5 Times Full Scale | N/A 1.5 Times Full Scale | N/A 2 Times Full Scale | N/A 2 Times Full Scale | ||||
Burst Pressure | N/A 3 Times Full Scale | N/A 3 Times Full Scale | N/A 9 Times Full Scale | N/A 9 Times Full Scale | ||||
Measuring Element | N/A 17-4PH Stainless Steel | |||||||
Connection Material | N/A 316 Stainless Steel | |||||||
Environmental Rating | N/A Ingress Protection (IP65); Ingress Protection (IP67) M12x1 electrical connection for pressure ranges 0 psig to 1,500 psig or higher | |||||||
Electrical Protection | N/A Reverse polarity, over-voltage and short circuit protection | |||||||
Shock According to International Electrotechnical Commission (IEC) 60068-2-27 | N/A 1,000 g | |||||||
Vibration According to International Electrotechnical Commission (IEC) 60068-2-6 | N/A 20 g | |||||||
Approximate Weight | N/A 1.75 oz | |||||||
Warranty | N/A 3 yr | |||||||
Options | N/A | N/A | N/A | N/A Threaded Orifice | ||||
Standard Orifice | N/A 1.0 mm | |||||||
Application |
N/A
|
|||||||
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
|||||||
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
|||||||
Additional Information |
N/A
|
|||||||
Assembly Options | N/A NOSHOK offers multiple assembly options to meet your specific system requirements. Consult factory to discuss your customized solution. | |||||||
Diaphragm Seals | N/A NOSHOK offers a wide variety of standard & elevated pressure, and reduced pressure replaceable and non-replaceable diaphragm seals, designed to isolate and/or protect the pressure measuring instrument from corrosive, viscous, contaminated or very high temperature process media. | |||||||
Digital Indicators | N/A NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. | |||||||
Distribution Manifolds | N/A NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths. | |||||||
Pressure Snubbers - Piston Type |
N/A
|
|||||||
Pressure Snubbers - Sintered Type |
N/A
|
|||||||
Steam Syphons |
N/A
|
|||||||
Swivel Adapters |
N/A
|
|||||||
Response Time | N/A <2 ms (between 10% and 90% full scale); restrictor port I.D. to dampen pulsations | |||||||
Related Items |
N/A
102-MFS, 1/4" National Pipe Thread (NPT), Male x Female, 316 Stainless Steel, 0.172" Orifice Hard Seat Mini Valve 602-MFS, 1/4" National Pipe Thread (NPT), Male x Female, 316 Stainless Steel, Hard Seat, 0.187" Orifice Block and Bleed Valve |
|||||||
|