Type |
N/A Submersible Level Transmitter |
Series |
N/A 611 |
Pressure Range1 | N/A 0 to 15 psig36.6 ftH2O |
Full Scale Best Fit Straight Line (BFSL) Accuracy (±) |
N/A ± 1.0% of span % |
Note for Accuracy |
N/A
Includes non-linearity, hysteresis, zero offset and end value deviation per IEC 61298-2 Accuracy after turndown via HART®, ≤ ±1.25% of scaled span (0.75% optional) Temperature sensor 14 ºF to 176 ºF (-10 ºC to 80 ºC): ≤ ± 3.3 ºF. |
Output Signal |
N/A 4 mA to 20 mA, 2-wire |
Process Connections |
N/A Nose Cone |
Electrical Connection |
N/A Standard Polyurethane (PUR) Cable, Optional Water-Blocked Polyvinyl Chloride (PVC) Cable (200+ psi Only), Optional Fluorinated Ethylene Propylene (FEP) Cable (38) |
Options |
N/A Cable Clamp, Cable Junction Box (NEMA 4X) |
Style |
N/A Level Transmitter |
Approximate Weight |
N/A 10.6 oz |
Storage Temperature [Min] |
N/A -40 ºC-40 ºF |
Storage Temperature [Max] |
N/A 80 ºC176 ºF |
Optional Accuracy |
N/A ± 0.5 of span |
Optional Housing Material |
N/A 318 LN |
Warranty |
N/A 3 yr |
Stability |
N/A ≤ ± 0.1% of span per year |
Switch on Time (Output signals without HART®) |
N/A ≤ 150 ms |
Switch on Time (Output Signals with HART®) |
N/A ≤ 250 ms |
Settling Time (Output Signals without HART®) |
N/A ≤ 100 ms |
Settling Time (Output Signals with HART®) |
N/A ≤ 250 ms |
Durability |
N/A < 100,000,000 full scale cycles |
Power Requirement2 |
N/A
4mA to 20 mA: 8 Vdc to 36 Vdc 4 mA to 20 mA and HART®: 12-36 Vdc 0.1 to 2.5 Vdc: 3.6 - 36 Vd |
Load Limitations |
N/A
4 mA to 20 mA: ≤ (Vpower - 8 V) / 0.022 A 4 mA to 20 mA and HART®: ≤ (Vpower - 9.6 V) / 0.022 A |
Proof Pressure |
N/A 5 Times Range |
Measuring Element |
N/A
Cap: Polyvinylidene Fluoride (PVDF) Sensor: 316 stainless steel, options Hastelloy C-276 Cable: Polyurethane, optional FEP |
Connection Material |
N/A 316 Stainless Steel |
Housing Material |
N/A 316 Stainless Steel |
Environmental Rating |
N/A Ingress Protection (IP68) |
Electromagnetic Rating |
N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
Electrical Protection |
N/A Reverse polarity protection, short circuit and resistance to overvoltage :DC 40V and increased overvoltage for lightning protection. Normal discharge current ≤ 10 kA, Rise time 8/20 µs |
Submersion Depth [Max] |
N/A 325 ft100 m |
Vibration According to International Electrotechnical Commission (IEC) 60068-2-6 |
N/A 4 g |
Cable Length |
N/A 70 ft |
Compensated Temperature Range |
N/A 32 to 176 ºF0 to 80 ºC |
Note for Compensated Temperature Range |
N/A Effect ± 0.01%/ºF for zero and span |
Standard Media Temperature Range |
N/A 14 to 122 ºF-10 to 50 ºC |
Optional Media Temperature Range |
N/A -40 to 176 ºF-40 to 80 ºC |
Prop 65 Warnings |
N/A
![]() |
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Application |
N/A
|
Additional Information |
N/A
|
Options and Accessories |
N/A
|