Type |
N/A Electronic Indicating Pressure Switch |
Series |
N/A 800 |
Switching Function |
N/A 2 Normally Open (N.O.) or 2 Normally Closed (N.C.) (Positive-Negative-Positive (P-N-P) or Negative-Positive-Negative (N-P-N)) |
Process Connection Size |
N/A 1/4 in |
Process Connection |
N/A Male National Pipe Thread (MNPT) |
Switch Adjustable Range |
N/A 0 to 5,000 psig |
Electrical Connection |
N/A M12 x 1 (4-pin) |
Accuracy |
N/A ≤ 0.5% of span |
Service Life |
N/A 10,000,000 load cycles |
Display |
N/A 14 segment-LED, red 4-digit, height 0.35" |
Direct Current (DC) Voltage |
N/A 15 to 35 V |
Current Consumption |
N/A
Max. 45 mA for versions without 4-20 mA output signal Max. 70 mA for versions with 4-20 mA output signal Total consumption max. 600 mA including switching current |
Proof Pressure |
N/A 2 Times Full Scale |
Measuring Element |
N/A
<150 psi: 316L Stainless steel ≥ 150 psi: 316L, PH grade Stainless steel |
Housing Material |
N/A 304 Stainless Steel |
Connection Material |
N/A 316 Stainless Steel |
Degree of Protection |
N/A Ingress Protection (IP65) and Ingress Protection (IP67) per International Electrotechnical Commission (IEC) 60529 |
Industry Standards/Certifications |
N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
Electrical Protection |
N/A Protected against reverse polarity, over-voltage and short circuit |
Shock According to International Electrotechnical Commission (IEC) 60068-2-27 |
N/A < 50 g |
Vibration According to International Electrotechnical Commission (IEC) 60068-2-6 |
N/A < 20 g |
Weight |
N/A 0.49 lb |
Options |
N/A Threaded Orifice |
Related Items |
N/A
102-MFS, 1/4" National Pipe Thread (NPT), Male x Female, 316 Stainless Steel, 0.172" Orifice Hard Seat Mini Valve 602-MFS, 1/4" National Pipe Thread (NPT), Male x Female, 316 Stainless Steel, Hard Seat, 0.187" Orifice Block and Bleed Valve |
Operating Temperature [Min] |
N/A -20 ºC-4 ºF |
Operating Temperature [Max] |
N/A 70 ºC158 ºF |
Media Temperature Range |
N/A -20 to 80 ºC-4 to 185 ºF |
Ambient Temperature Range |
N/A -20 to 80 ºC-4 to 176 ºF |
Compensated Temperature Range |
N/A 0 to 80 ºC32 to 176 ºF |
Switch Parameter |
N/A Individually adjustable via external control keys |
Switching Number |
N/A 1 2 |
Contact Rating Current [Max] |
N/A 250 mA |
Response Time |
N/A ≤ 5 ms |
Switch Point |
N/A 0.25 to 100% of full scale |
Hysteresis |
N/A Fully Adjustable |
Output Signal |
N/A 4 mA to 20 mA or 0 Vdc to 10 Vdc; programmable and freely adjustable |
Accuracy for Transmitter Parameter |
N/A ≤ ±0.5% of span including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2) |
Non-Repeatability |
N/A < 0.1% of span (IEC 61298-2) |
Adjustment |
N/A Freely scalable within the range of 5:1 |
Application |
N/A
|
Prop 65 Warnings |
N/A
![]() |
Additional Information |
N/A
|
Options and Accessories |
N/A
|
Diaphragm Seals |
N/A NOSHOK offers a wide variety of standard & elevated pressure, and reduced pressure replaceable and non-replaceable diaphragm seals, designed to isolate and/or protect the pressure measuring instrument from corrosive, viscous, contaminated or very high temperature process media. |
Digital Indicators |
N/A NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. |
Distribution Manifolds |
N/A NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths. |
Pressure Snubbers - Piston Type |
N/A
|
Pressure Snubbers - Sintered Type |
N/A
|
Seal & Pressure Transmitter/Switch Assembly For Wastewater, Chemical Feed |
N/A The NOSHOK All Non-Metallic Diaphragm Seal & Pressure Transmitter/Switch assembly is ideal for water, wastewater & chemical feed applications. |
Steam Syphons |
N/A
|
Swivel Adapters |
N/A
|