Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Type |
N/A Pressure Transmitter |
Weight |
N/A 12 oz |
Storage Temperature [Min] |
N/A -40 ºC-40 ºF |
Storage Temperature [Max] |
N/A 105 ºC221 ºF |
Housing Material |
N/A 316 Stainless Steel |
Connection Size |
N/A G1/2B |
Pressure Range |
N/A 0 to 300 psig |
Accuracy |
N/A 0.25 % |
Output Signal |
N/A 4 mA to 20 mA, 2-wire |
Environmental Rating |
N/A Ingress Protection (IP67) |
Series |
N/A 316 Stainless Steel Flush Diaphragm |
Electrical Connection |
N/A 1/2 in. NPT male conduit with 6 ft integral cable |
Connection Material |
N/A 316 Stainless Steel |
Absolute Pressure Range |
N/A 0 to 100 psia0 to 15 psia |
Stability |
N/A ≤ ±0.2% full scale for 1 year, non-accumulating |
Response Time |
N/A ≤1 ms |
Service Life |
N/A > 100,000,000 Load Cycles |
Power Requirement |
N/A
10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire) 6 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire, 0.5 Vdc to 4.5 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) |
Measuring Element |
N/A 622 Series is 316 stainless steel with NBR O-Ring; (FKM O-Ring Optional) |
Electrical Protection |
N/A Reverse polarity, over-voltage and short circuit protected |
Electromagnetic Rating |
N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
Shock According to International Electrotechnical Commission (IEC) 60068-2-27 |
N/A 1,000 g |
Vibration According to International Electrotechnical Commission (IEC) 60068-2-6 |
N/A 20 g |
Compensated Temperature Range |
N/A 32 to 176 ºF0 to 80 ºC |
Media Temperature Range (T6) |
N/A -40 to 131 ºF-40 to 55 ºC |
Media Temperature Range (T5) |
N/A -40 to 158 ºF-40 to 70 ºC |
Media Temperature Range (T4) |
N/A -40 to 212 ºF-40 to 100 ºC |
Ambient Temperature Range (T6) |
N/A -40 to 140 ºF-40 to 60 ºC |
Ambient Temperature Range (T5) |
N/A -40 to 167 ºF-40 to 75 ºC |
Ambient Temperature Range (T4) |
N/A -40 to 221 ºF-40 to 105 ºC |
Current for 4 to 20 Milliampere (mA) |
N/A 0.020 A |
Resistance for 1 to 5 Direct Current (DC) Voltage, 3-Wire |
N/A ≥ 10,000 O |
Application |
N/A
|
Additional Information |
N/A
NOSHOK 621 and 622 Series transmitters are Factory Mutual and Canadian Standards Association approved for use in hazardous location applications as follows:
|
Options and Accessories |
N/A
|
Assembly Option for Indication, Output, and Isolation/Bleed |
N/A
NOSHOK offers multiple assembly options to meet your specific system requirements. Consult factory to discuss your customized solution. For example, you can simplify your system with this easy-to-install solution from NOSHOK. Three simple components that require a single threaded connection in your piping system will provide local indication, analog output and block/isolate with bleed function. This product grouping is an ideal solution for a variety of applications including oil and gas, and is available in several high pressure ranges, including 5,000, 10,000 and 15,000 psi. Special design for Shale Gas applications. This example represents a general solution; however, we offer a diverse range of gauges, transmitters and valves which are available with a variety of connection options and ranges to suit your needs. (Photo shows 40-400 Series Pressure Gauge (Local Indication), 621 Series Pressure Transmitter (Control Output), and 200 Series Multi-Port Valve (Block/Isolate & Bleed). |
Digital Indicators |
N/A NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. |
Pressure Snubbers - Piston Type |
N/A
|
Pressure Snubbers - Sintered Type |
N/A
|
Steam Syphons |
N/A
|
Swivel Adapters |
N/A
|
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|