Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Type |
N/A Transmitter |
Series |
N/A 800 |
Electromagnetic Rating |
N/A European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:1997/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection |
Connection Type |
N/A Male National Pipe Thread (MNPT) |
Wetted Materials |
N/A 316 Stainless Steel |
Temperature Ranges [Min] |
N/A 0 ºF |
Temperature Ranges [Max] |
N/A 140 ºF |
Housing Material |
N/A 316 Stainless Steel |
Connection Size |
N/A 1/4 in |
Output Signal |
N/A 0 to 10 Vdc, 3-Wire |
Electrical Connection |
N/A DIN EN 175301-803 Form A |
Power Supply |
N/A
10 to 30 Vdc (4 to 20 mA, 2-Wire) 10 to 30 Vdc (0 to 5 Vdc, 3-Wire) 10 to 30 Vdc (1 to 5 Vdc, 3-Wire) 14 to 30 Vdc (0 to 10 Vdc, 3-Wire) |
Accuracy |
N/A Class B + (±0.5 % Best Fit Straight Line (BFSL)) |
Storage Temperature [Max] |
N/A 85 ºC185 ºF |
Storage Temperature [Min] |
N/A -40 ºC-40 ºF |
Standard Temperature Ranges |
N/A -40 to 120 ºF50 to 400 ºF |
Sensor Protection |
N/A Burnout Protected from 3.3 to 23 mA |
Measuring Element |
N/A Class B per Norm European Standards (EN) 60751 (International Electrotechnical Commission (IEC 751)) |
Output |
N/A
±[0.30 + 0.005 ltl] ºC ±0.5% Full Scale |
Load Limitations |
N/A
≤(VPower - 10)/0.020 Amp for 4 to 20 mA output ≤5000 Ω for 1 to 5 Vdc output ≤10, 000 Ω for 0 to 10 Vdc output ≤4500 Ω for 0.5 to 4.5 Vdc output |
Pressure Rating |
N/A 725 psi |
Ambient Temperature Range |
N/A -40 to 185 ºF-40 to 85 ºC |
Environmental Protection |
N/A Ingress Protection (IP65) According to Norm European Standards (EN) 60529/(International Electrotechnical Commission (IEC 529)) |
Electrical Protection |
N/A Reverse polarity, over-voltage and short circuit protection |
Approximate Weight |
N/A 4 oz |
Warranty |
N/A 3 yr |
Stem Diameters |
N/A 6 mm |
Stem Lengths |
N/A 2-1/2 in |
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
Application |
N/A
|
Limitations Which Apply Are |
N/A
These units must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.'s equipment and personnel or a certified test facility specializing in this type of evaluation. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
Additional Information |
N/A
|
1800 Series Attachable Loop-Powered Digital Indicators |
N/A NOSHOK 1800 Series Attachable Loop-Powered Digital Indicators can be fitted to certain NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the DIN EN 175301-803 Form A Electrical Connection. |
Thermowells |
N/A Thermowells allow a temperature instrument to be removed and replaced without shutting down and draining the process, and reduce the possibility of damage to the temperature instrument. |