Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Items |
/Asset/Type-12-Diaphragm-Seals.jpg 12-02S-S-12 1/4" National Pipe Thread (NPT) Instrument Connection, 316 Stainless Steel Type 12 Diaphragm Seal with 316 Stainless Steel Diaphragm and 1-1/2" Sanitary Pipe |
/Asset/Type-12-Diaphragm-Seals.jpg 12-02S-S-16 1/4" National Pipe Thread (NPT) Instrument Connection, 316 Stainless Steel Type 12 Diaphragm Seal with 316 Stainless Steel Diaphragm and 2" Sanitary Pipe |
/Asset/Type-12-Diaphragm-Seals.jpg 12-04S-S-12 1/2" National Pipe Thread (NPT) Instrument Connection, 316 Stainless Steel Type 12 Diaphragm Seal with 316 Stainless Steel Diaphragm and 1-1/2" Sanitary Pipe |
/Asset/Type-12-Diaphragm-Seals.jpg 12-04S-S-16 2 in. Sanitary Pipe Size, Clamped-Style, American Society of Mechanical Engineers - Bioprocessing Equipment (ASME-BPE), Non-Replaceable Type 12 Sanitary Diaphragm Seal |
||||
Description |
N/A
|
|||||||
Type | N/A Diaphragm Seal | |||||||
Style | N/A Non-Replaceable Diaphragm Seal | |||||||
Instrument Connection Size | N/A 1/4 in | N/A 1/4 in | N/A 1/2 in | N/A 1/2 in | ||||
Instrument Connection Type | N/A National Pipe Thread (NPT) | |||||||
Upper Housing Material | N/A 316 Stainless Steel | |||||||
Diaphragm Material | N/A 316 Stainless Steel | |||||||
Sanitary Pipe Sizes | N/A 1-1/2 in | N/A 2 in | N/A 1-1/2 in | N/A 2 in | ||||
Process Connection | N/A National Pipe Thread (NPT) | |||||||
Seal Type | N/A Sanitary clamp, welded diaphragm | |||||||
Pressure [Max] | N/A Determined by the clamping device and piping system. | |||||||
Instrument Type | N/A Gauges, Transducers, Switches | |||||||
Instrument Gauge Size | N/A 2-1/2 to 4 in | |||||||
Pressure [Min] for Gauges 2-1/2 to 4 in. Size | N/A 0 to 30 psig | |||||||
Pressure [Min] for Transducers | N/A 0 to 30 psig | |||||||
Pressure [Min] for Switches | N/A 0 to 30 psig | |||||||
Upper Housing Type | N/A Continuous Duty | |||||||
Diaphragm Size | N/A 1.4 in | N/A 1.9 in | N/A 1.4 in | N/A 1.9 in | ||||
Diaphragm Displacement | N/A 190 mm³ | N/A 490 mm³ | N/A 190 mm³ | N/A 490 mm³ | ||||
O-Ring Temperature Limits for Nitrile Butadiene Rubber (NBR) Material | N/A -40 to 250 ºF | |||||||
O-Ring Temperature Limits for Polytetrafluoroethylene (PTFE) Material | N/A -400 to 400 ºF | |||||||
O-Ring Temperature Limits for Fluorocarbon (FKM) Material | N/A -10 to 400 ºF | |||||||
Diaphragm Pressure Limits for Polytetrafluoroethylene (PTFE) Material | N/A 2,000 psi | |||||||
Diaphragm Pressure Limits for Fluorocarbon (FKM) Material | N/A 2,000 psi | |||||||
Diaphragm Temperature Limits for Polytetrafluoroethylene (PTFE) Material | N/A -40 to 400 ºF | |||||||
Diaphragm Temperature Limits for Fluorocarbon (FKM) Material | N/A -10 to 400 ºF | |||||||
Note for Diaphragm Pressure and Temperature Limits | N/A Metallic diaphragms determined by pressure range of seal type, restricted to temperature range of fill fluid. | |||||||
Maximum Pressure Limits for Glass Transition Temperature (Tg), Tetoron Cotton (TC) Bottom Housing Material | N/A 200 psi | |||||||
Maximum Pressure Limits for Polyvinylidene Fluoride (PVDF) Bottom Housing Material | N/A 200 psi | |||||||
Maximum Pressure Limits for Polyvinyl Chloride (PVC) Bottom Housing Material | N/A 80 psi125 psi200 psi | |||||||
Maximum Pressure Limits for Polypropylene (PP) Bottom Housing Material | N/A 200 psi | |||||||
Maximum Temperature Limits for Glass Transition Temperature (Tg), Tetoron Cotton (TC) Bottom Housing Material | N/A 150 ºF | |||||||
Maximum Temperature Limits for Polyvinylidene Fluoride (PVDF) Bottom Housing Material | N/A 180 ºF | |||||||
Maximum Temperature Limits for Polyvinyl Chloride (PVC) Bottom Housing Material | N/A 74 ºF125 ºF150 ºF | |||||||
Maximum Temperature Limits for Polypropylene (PP) Bottom Housing Material | N/A 140 ºF | |||||||
Note for Maximum Pressure and Temperature Limits Bottom Housing Material | N/A Metallic lower housings determined by pressure range of seal type, restricted to temperature range of fill fluid. | |||||||
Application |
N/A
|
|||||||
Additional Information |
N/A
|
|||||||
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
|
|||||||
Cooling Elements |
N/A
|
|||||||
Diaphragm Seal Fill Options |
N/A
|
|||||||
Distribution Manifolds | N/A NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths. | |||||||
Plain and Armored Capillaries |
N/A
|
|||||||
Sanitary Clamps and Gaskets |
N/A
1-1/2" (CR 12) 2" (CR 16) 2-1/2" (CR 20) 3" (CR 24) NBR Gasket 1-1/2" (BG 12) 2" (BG 16) 2-1/2" (BG 20) 3" (BG 24) PTFE Gasket 1-1/2" (TG 12) 2" (TG 16) 2-1/2" (TG 20) 3" (TG 24) |
|||||||
Stock | N/A Yes | |||||||
|