Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Use PT Series Part Number Crossover Tool to convert from 100, 200, 300 and 615 Series transmitters to new PT Series transmitters.
Items |
/Asset/600-700-Series-Pressure-Gauges.jpg 45-640-10000-psi 4.5" Brass Internals, 10,000 psi, 1/4" National Pipe Thread (NPT) Male Bottom Connection Pressure Gauge |
/Asset/600-700-Series-Pressure-Gauges.jpg 45-640-10000-psi/kPa 4.5" Brass Internals, 10,000 psi/kPa, 1/4" National Pipe Thread (NPT) Male Bottom Connection Pressure Gauge |
/Asset/600-700-Series-Pressure-Gauges.jpg 45-640-1000-psi 4.5" Brass Internals, 1,000 psi, 1/4" National Pipe Thread (NPT) Male Bottom Connection Pressure Gauge |
/Asset/600-700-Series-Pressure-Gauges.jpg 45-640-1000-psi/kPa 4.5" Brass Internals, 1,000 psi/kPa, 1/4" National Pipe Thread (NPT) Male Bottom Connection Pressure Gauge |
/Asset/600-700-Series-Pressure-Gauges.jpg 45-640-100-psi 4.5" Brass Internals, 100 psi, 1/4" National Pipe Thread (NPT) Male Bottom Connection Pressure Gauge |
|||||
Description |
N/A
|
|||||||||
Type | N/A Pressure Gauge | |||||||||
Connection Type | N/A National Pipe Thread (NPT) | |||||||||
Full Scale Accuracy (±) | N/A 0.5 % | |||||||||
Connection Size | N/A 1/4 in | |||||||||
Lens | N/A Acrylic | |||||||||
Dial | N/A Aluminum, white background with black scale. UV resistant. | |||||||||
Bayonet Ring Material | N/A Threaded Black PBT | |||||||||
Gauge Size | N/A 4.5 in | |||||||||
Connection Location | N/A Bottom | |||||||||
Scale Option | N/A psi Single Scale | N/A psi/kPa Dual Scale | N/A psi Single Scale | N/A psi/kPa Dual Scale | N/A psi Single Scale | |||||
Case Material | N/A Turret Style Black Polypropylene Case Solid Front, Safety Case with Blow-Out Back | |||||||||
Case Type | N/A Brass, Dry, Bottom Connection | |||||||||
Media Temperature Range | N/A -4 to 150 ºF-20 to 65 ºC | |||||||||
Ambient Temperature Range | N/A -40 to 150 ºF-40 to 65 ºC | |||||||||
Media Temperature Range (Glycerin Fill) | N/A | |||||||||
Media Temperature Range (Special Fill) | N/A | |||||||||
Ambient Temperature Range (Glycerin Fill) | N/A | |||||||||
Ambient Temperature Range (Special Fill) | N/A | |||||||||
Short Term/Intermittent Temperature | N/A | |||||||||
Measuring Element | N/A 316 Stainless Steel Coiled Safety Bourdon Tube | N/A 316 Stainless Steel Coiled Safety Bourdon Tube | N/A Copper Alloy C-Type Bourdon Tube | N/A Copper Alloy C-Type Bourdon Tube | N/A Copper Alloy C-Type Bourdon Tube | |||||
Connection Material | N/A Brass | |||||||||
Pressure Range | N/A 0 to 10,000 psi | N/A 0 to 10,000 psi | N/A 0 to 1,000 psi | N/A 0 to 1,000 psi | N/A 0 to 100 psi | |||||
Series | N/A 600 | |||||||||
Pointer | N/A Balanced micro-adjustable aluminum, black finish | |||||||||
Movement | N/A Brass and nickel-silver with highly polished bearing surfaces. An internal zero stop is standard. | |||||||||
Fill Liquid | N/A | |||||||||
Warranty | N/A 1 yr | |||||||||
Options | N/A | |||||||||
Application |
N/A
|
|||||||||
Prop 65 Warnings |
N/A
WARNING: This product can expose you to chemicals including Lead and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
|||||||||
Working Pressure Limitations |
N/A
Dynamic Pressure The working pressure should be limited to 60% of the dial range. Max. 0.9x full scale Static Pressure The working pressure, where no sharp fluctuations occur, should be limited to 90% of the dial range. Max. 1x full scale. Short term max. 1.5x full scale (<10,000 psi). |
|||||||||
Limitations Which Apply Are |
N/A
|
|||||||||
Caution |
N/A
Operating conditions including, but not limited to, system pressure, media compatibility and ambient conditions must be considered when selecting gauges and accessories. Improper selections and use of gauges could possibly cause gauge failure and lead to possible property damage or personal injury. Refer to the American National Standard ANSI B40.1 for the correct selection and use of gauges. A copy of this standard may be obtained from the American Society of Mechanical Engineers, United Engineering Center, 345 East 47th Street, New York, NY 10017. In keeping with and for purposes of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. |
|||||||||
Installed Options and Accessories |
N/A
Available
|
|||||||||
Uninstalled Options and Accessories |
N/A
|
|||||||||
Assembly Options | N/A NOSHOK offers multiple assembly options to meet your specific system requirements. Consult factory to discuss your customized solution. | |||||||||
Diaphragm Seals | N/A NOSHOK offers a wide variety of standard & elevated pressure, and reduced pressure replaceable and non-replaceable diaphragm seals, designed to isolate and/or protect the pressure measuring instrument from corrosive, viscous, contaminated or very high temperature process media. | |||||||||
Distribution Manifolds | N/A NOSHOK's Distribution Manifolds connect multiple instruments to one diaphragm seal, eliminating multiple connections that lead to possible leak paths. | |||||||||
Metric Dials and Customized Special Dials |
N/A
|
|||||||||
Pressure Snubbers - Piston Type |
N/A
|
|||||||||
Pressure Snubbers - Sintered Type |
N/A
|
|||||||||
Reid Vapor Test Gauges |
N/A
|
|||||||||
Steam Syphons |
N/A
|
|||||||||
Swivel Adapters |
N/A
|
|||||||||
Warnings | N/A | |||||||||
Related Items |
N/A
402-MFC, 1/4" National Pipe Thread (NPT), Male x Female, Steel, Hard Seat, 0.187" Orifice Needle Valve 602-MFC, 1/4" National Pipe Thread (NPT), Male x Female, Steel, Hard Seat, 0.187" Orifice Block and Bleed Valve 602-MFS, 1/4" National Pipe Thread (NPT), Male x Female, 316 Stainless Steel, Hard Seat, 0.187" Orifice Block and Bleed Valve 702-MFC, 1/4" National Pipe Thread (NPT), Male x Female, Steel, Soft Seat, 0.187" Orifice Block and Bleed Valve |
|||||||||
|